Page 126 - IJEEE-2023-Vol19-ISSUE-1
P. 126

122 |                                                                              Al-Atbee, Kadhem, Harden, & Abdulhassan
                                                      S2-S3
       S1-S4

       S5

       S6
         S7

                                                 Fig. 4: The Timing signals of the control circuit.

The circuit controller is made up of a variety of logical and
mathematical MATLAB functions, and it is these functions
that are responsible for producing the pulses to control the
proposed inverter.
Figure 5 depicts the output voltage of the inverter with 15
levels that has been proposed. Figure 6 illustrates the total
harmonic distortion, or THD, that is present in the output
voltage. Examining the diagram, one can observe that the
THD equal to 8.24 when the modulation index m is about
0.95.

       Fig. 5: The 15-level inverter output voltage.  Fig. 6: The total harmonic distortion (THD) of the 15-level
                                                                                     inverter.

                                                                               IV. CONCLUSION

                                                                 Multi-level inverters are becoming increasingly
                                                      significant in today's applications. A 15-level inverter is
                                                      presented in this work. The proposed inverter may produce a
                                                      high-quality output voltage while minimizing overall
                                                      harmonic distortion (THD). In terms of performance, it
   121   122   123   124   125   126   127   128