Iraqi Journal for Electrical and Electronic Engineering
Login
Iraqi Journal for Electrical and Electronic Engineering
  • Home
  • Articles & Issues
    • Latest Issue
    • All Issues
  • Authors
    • Submit Manuscript
    • Guide for Authors
    • Authorship
    • Article Processing Charges (APC)
    • Proofreading Service
  • Reviewers
    • Guide for Reviewers
    • Become a Reviewer
  • Policies
    • Publication Ethics
    • Plagiarism
    • Allegations of Misconduct
    • Appeals and Complaints
    • Corrections and Withdrawals
    • Copyright Policy
    • Open Access
    • Archiving Policy
  • About
    • About Journal
    • Aims and Scope
    • Editorial Team
    • Journal Insights
    • Peer Review Process
    • Abstracting and indexing
    • Announcements
    • Contact

Search Results for Jovin Deglus

Article
A Novel Hybrid Optimization Approach for Allocation of Distributed Generation in Distribution Power Network

Jarabala Ranga, Vijayakumar G, Rajakumar P, Gopika Venu, Jovin Deglus, Kesavan D, Sundar R

Pages: 157-167

PDF Full Text
Abstract

This study aims to assimilate distributed generation (DG) unit using a novel hybrid technique to improve the efficiency of electric power distribution networks by minimizing the real power losses (RPL) and enhancing the bus voltages (BV). A hybrid technique has been implemented by combining the features of nature-inspired algorithms namely hunter-prey optimizer (HPO) and ant lion optimizer (ALO) algorithms. The exploitation characteristic of ALO and exploration characteristic of HPO is utilized to optimize single DG in radial distribution power network (DPN). The efficacy of the suggested hybrid optimization technique is validated using MATLAB/Simulink software tool. The proposed hybrid technique was executed to optimize type I and type III DG in a balanced IEEE 69-bus radial DPN. The optimized type I and type III DG placement minimized the real power losses of a test system to 71.23 kW and 20.38 kW, respectively. Additionally, the least bus voltage of the test system improved to 0.9776p.u and 0.9843p.u following type I and type III DG allocation. The optimized allocation of type I DG and type III DG has resulted in 68.34% and 90.94% power loss reduction, respectively and enhanced the minimum bus voltage of the test system by 7.5% and 8.3%, respectively. The efficacy of the proposed hybrid methodology was investigated by relating its simulation outcome with other optimization methodologies present in the literature. The comparative results revealed that the proposed hybrid optimization technique provided better RPL minimization at improved BV than the compared optimization techniques.

1 - 1 of 1 items

Search Parameters

×

The submission system is temporarily under maintenance. Please send your manuscripts to

Go to Editorial Manager
Journal Logo
Iraqi Journal for Electrical and Electronic Engineering

College of Engineering, University of Basrah

  • Copyright Policy
  • Terms & Conditions
  • Privacy Policy
  • Accessibility
  • Cookie Settings
Licensing & Open Access

CC BY 4.0 Logo Licensed under CC-BY-4.0

This journal provides immediate open access to its content.

Editorial Manager Logo Elsevier Logo

Peer-review powered by Elsevier’s Editorial Manager®

Copyright © 2026 College of Engineering, University of Basrah, its licensors, and contributors. All rights reserved, including those for text and data mining, AI training, and similar technologies. For all open access content, the relevant licensing terms apply.