The Analysis of Sub-Synchronous Resonance in a Wind Farm for a Doubly-Fed Induction Generator Using Modern Analytical Method

Abstract

The occurrence of Sub-Synchronous Resonance (SSR) phenomena can be attributed to the interaction that takes place between wind turbine generators and series-compensated transmission lines. The Doubly-Fed Induction Generator (DFIG) is widely recognized as a prevalent generator form employed in wind energy conversion systems. The present paper commences with an extensive exposition on modal analysis techniques employed in a series of compensated wind farms featuring Doubly Fed Induction Generators (DFIGs). The system model encompasses various components, including the aerodynamics of a wind turbine, an induction generator characterized by a sixth-order model, a second- order two-mass shaft system, a series compensated transmission line described by a fourth-order model, controllers for the Rotor-Side Converter (RSC) and the Grid-Side Converter (GSC) represented by an eighth-order model, and a first-order DC-link model. The technique of eigenvalue-based SSR analysis is extensively utilized in various academic and research domains. The eigenvalue technique depends on the initial conditions of state variables to yield an accurate outcome. The non-iterative approach, previously employed for the computation of initial values of the state variables, has exhibited issues with convergence, lack of accuracy, and excessive computational time. The comparative study evaluates the time-domain simulation outcomes under different wind speeds and compensation levels, along side the eigenvalue analysis conducted using both the suggested and non-iterative methods. This comparative analysis is conducted to illustrate the proposed approach efficacy and precision. The results indicate that the eigenvalue analysis conducted using the proposed technique exhibits more accuracy, as it aligns with the findings of the simulations across all of the investigated instances. The process of validation is executed with the MATLAB program. Within the context of the investigation, it has been found that increasing compensation levels while simultaneously decreasing wind speed leads to system instability. Therefore, modifying the compensation level by the current wind speed is advisable.

References

  1. H. A. Mohammadpour and E. Santi, “Sub-synchronous resonance analysis in dfig-based wind farms: Definitions and problem identification — part i,” 2014 IEEE Energy Conversion Congress and Exposition (ECCE), pp. 812– 819, 2014.
  2. K. Padiyar, Analysis of subsynchronous resonance in power systems. Springer Science & Business Media, 2012.
  3. Y. Liu, J. Zheng, Q. Chen, Z. Duan, Y. Tian, M. Ban, and Z. Li, “Mmc-statcom supplementary wide-band damp- ing control to mitigate subsynchronous control interac- tion in wind farms,” International Journal of Electrical Power & Energy Systems, vol. 141, p. 108171, 2022.
  4. M. Ghafouri, U. Karaagac, J. Mahseredjian, and H. Karimi, “Ssci damping controller design for series- compensated dfig-based wind parks considering imple- mentation challenges,” IEEE Transactions on Power Systems, vol. 34, no. 4, pp. 2644–2653, 2019.
  5. J. Yao, X. Wang, J. Li, R. Liu, and H. Zhang, “Sub- synchronous resonance damping control for series- compensated dfig-based wind farm with improved parti- cle swarm optimization algorithm,” IEEE Transactions on Energy Conversion, vol. 34, no. 2, pp. 849–859, 2018.
  6. L. Wang, X. Xie, Q. Jiang, H. Liu, Y. Li, and H. Liu, “Investigation of ssr in practical dfig-based wind farms connected to a series-compensated power system,” IEEE Transactions on Power Systems, vol. 30, no. 5, pp. 2772– 2779, 2014.
  7. X. Xie, X. Zhang, H. Liu, H. Liu, Y. Li, and C. Zhang, “Characteristic analysis of subsynchronous resonance in practical wind farms connected to series-compensated transmissions,” IEEE Transactions on Energy Conver- sion, vol. 32, no. 3, pp. 1117–1126, 2017.
  8. P. Li, L. Xiong, F. Wu, M. Ma, and J. Wang, “Slid- ing mode controller based on feedback linearization for damping of sub-synchronous control interaction in dfig- based wind power plants,” International Journal of Elec- trical Power & Energy Systems, vol. 107, pp. 239–250, 2019.
  9. H. A. Mohammadpour and E. Santi, “Modeling and con- trol of gate-controlled series capacitor interfaced with a dfig-based wind farm,” IEEE Transactions on Industrial Electronics, vol. 62, no. 2, pp. 1022–1033, 2014.
  10. S. O. Faried, I. Unal, D. Rai, and J. Mahseredjian, “Utilizing dfig-based wind farms for damping subsyn- chronous resonance in nearby turbine-generators,” IEEE Transactions on Power Systems, vol. 28, no. 1, pp. 452– 459, 2012.
  11. P.-H. Huang, M. S. El Moursi, W. Xiao, and J. L. Kirt- ley, “Subsynchronous resonance mitigation for series- compensated dfig-based wind farm by using two-degree- of-freedom control strategy,” IEEE Transactions on Power Systems, vol. 30, no. 3, pp. 1442–1454, 2014.
  12. A. E. Leon and J. A. Solsona, “Sub-synchronous inter- action damping control for dfig wind turbines,” IEEE Transactions on Power Systems, vol. 30, no. 1, pp. 419– 428, 2014.
  13. H. A. Mohammadpour, A. Ghaderi, and E. Santi, “Anal- ysis of sub-synchronous resonance in doubly-fed induc- tion generator-based wind farms interfaced with gate– controlled series capacitor,” IET Generation, Transmis- sion & Distribution, vol. 8, no. 12, pp. 1998–2011, 2014.
  14. H. A. Mohammadpour and E. Santi, Analysis of sub- synchronous resonance (SSR) in doubly-fed induction generator (DFIG)-based wind farms. Springer Nature, 2022.
  15. K.-H. Kim, T. L. Van, D.-C. Lee, S.-H. Song, and E.- H. Kim, “Maximum output power tracking control in variable-speed wind turbine systems considering rotor inertial power,” IEEE transactions on industrial elec- tronics, vol. 60, no. 8, pp. 3207–3217, 2012.
  16. M. Wu, L. Xie, L. Cheng, and R. Sun, “A study on the impact of wind farm spatial distribution on power system 270 | Abdulabbas, Salih, & Alawan sub-synchronous oscillations,” IEEE Transactions on Power Systems, vol. 31, no. 3, pp. 2154–2162, 2015.
  17. M. Wu and L. Xie, “Calculating steady-state operating conditions for dfig-based wind turbines,” IEEE Transac- tions on sustainable Energy, vol. 9, no. 1, pp. 293–301, 2017.
  18. M. Abdeen, H. Li, and L. Jing, “Improved subsyn- chronous oscillation detection method in a dfig-based wind farm interfaced with a series-compensated net- work,” International Journal of Electrical Power & En- ergy Systems, vol. 119, p. 105930, 2020.
  19. L. Fan and Z. Miao, “Mitigating ssr using dfig-based wind generation,” IEEE Transactions on Sustainable Energy, vol. 3, no. 3, pp. 349–358, 2012.
  20. A. K. Abdulabbas, M. A. Alawan, and D. K. Shary, “Limits of reactive power compensation of a doubly fed induction generator based wind turbine system,” Bulletin of Electrical Engineering and Informatics, vol. 12, no. 5, pp. 2521–2534, 2023.
  21. M. R. A. Pahlavani and H. A. Mohammadpour, “Damp- ing of sub-synchronous resonance and low-frequency power oscillation in a series-compensated transmission line using gate-controlled series capacitor,” Electric Power Systems Research, vol. 81, no. 2, pp. 308–317, 2011.
  22. L. Piyasinghe, Z. Miao, J. Khazaei, and L. Fan, “Impedance model-based ssr analysis for tcsc compen- sated type-3 wind energy delivery systems,” IEEE Trans- actions on Sustainable Energy, vol. 6, no. 1, pp. 179– 187, 2014.
  23. Y. Lei, A. Mullane, G. Lightbody, and R. Yacamini, “Modeling of the wind turbine with a doubly fed induc- tion generator for grid integration studies,” IEEE transac- tions on energy conversion, vol. 21, no. 1, pp. 257–264, 2006.
  24. F. Mei and B. Pal, “Modal analysis of grid-connected doubly fed induction generators,” IEEE transactions on energy conversion, vol. 22, no. 3, pp. 728–736, 2007.
  25. L. Fan, C. Zhu, Z. Miao, and M. Hu, “Modal analy- sis of a dfig-based wind farm interfaced with a series compensated network,” IEEE Transactions on Energy Conversion, vol. 26, no. 4, pp. 1010–1020, 2011.